SPD SmartGlass™ - Care & Maintenance
Trouble Shooting
In the unusual event of your SmartGlass window not correctly working please follow the directions below or contact us.
SPD SmartGlass™ does not turn clear when switched ON
1. Check fuses on switchboard
2. Measure the primary of the transformer: after the UPS
3. If the power conditioner is not powered, check the switch
4. If the TPC is under tension, measure the secondary
5. If the secondary is not under tension, check the internal fuse
6. If the internal fuse is intact, the defect is inside the power conditioner and it must be replaced
7. If the secondary is under tension, check wiring and connection to the glass
8. Check input voltage to glass connections.
SPD SmartGlass™ remains clear in OFF-mode
The Cause can only be a defective switch, check and replace if necessary.